LS ELECTRIC XGB PLC, 24 VDC REQUIRED, ETHERNET, SERIAL AND USB B PORTS, DISCRETE INPUT: 16-POINT, DC, DISCRETE OUTPUT: 16-POINT, SINKING, 4 HIGH-SPEED INPUT POINT(S), 6 HIGH-SPEED OUTPUT POINT(S). REQUIRES XTB-40H TERMINAL BLOCK AND C40HH-XXSB-XBI CABLE.
| Brand | LS Electric XGB |
| Item | PLC |
| Battery Backup | No |
| Includes | 3-wire power cable and 5-pin serial communication terminal block |
| Voltage Type | DC |
| Requires | XTB-40H terminal block and C40HH-xxSB-XBI cable |
| Load Current | (12) 0.1A/point, (4) 0.5A/point |
| Communication Port and Connection Type(s) | (1) Ethernet 10/100Base-T (RJ45) + (1) RS-232/RS-485 (5-pin terminal) + (1) miniB-USB |
| Port Protocol(s) | Modbus RTU Master/Slave + Modbus ASCII Master/Slave + Modbus TCP Client/Server + LS XGT protocol Client/Server + programming and monitoring |
| Port Speed(s) | 10/100 Mbps + up to 115.2k baud |
| External Power Requirement | 24 VDC |
| Nominal Input Voltage | 24 VDC |
| Programming Software | XG5000 programming software v4.7 or later |
| Dangerous Goods | Battery Installed: Yes (not user replaceable) + Packaging Instructions: 970 + UN Number: UN3091 + Hazard Type: Lithium Batteries + Battery Type: Coin + Lithium Content: 0.01 |
| Discrete Input Type | Sinking/sourcing |
| Number of Non-Isolated Discrete Input Commons | 1 |
| Nominal Output Voltage | 12-24 VDC |
| Discrete Output Type | Sinking |
| Number of Non-Isolated Discrete Output Commons | 1 |
| Number of Points per Discrete Input Common | 16 |
| Number of Points per Discrete Output Common | 16 |
| Total Memory | 544 KB |
| User Data Memory | 160 KB |
| Programming Language | IEC 61131-3 ladder, structured text, sequential function chart and instruction list |
| Real Time Clock/Calendar | Yes |
| Retentive Memory | Yes |
| Maximum Expansion Modules Allowed | 7 |
| Number of Discrete Input Points | 16 |
| Number of Discrete Output Points | 16 |
| Maximum Number of PID Loops | 16 |
| Frequency Response | 200 kHz |
| Number of High-Speed Capable Input Points | 4 |
| High-Speed Counter(s) | up to (4) up counters + up to (4) down counters + up to (2) up/down counters + up to (2) pulse/direction (bi-directional) counters + up to (2) quadrature (A and B) counters |
| Frequency Measurement | up to (4) up counters + up to (4) down counters + up to (2) up/down counters + up to (2) pulse/direction (bi-directional) counters + up to (2) quadrature (A and B) counters |
| Interrupt(s) | up to (16) cycle time interrupts + up to (8) external input interrupts + up to (16) internal device interrupts + up to (4) high-speed counter interrupts + up to (1) positioning interrupt |
| Maximum Switching Frequency | 200 kHz |
| Number of High-Speed Capable Output Points | 6 |
| Output Pulse Mode(s) | up to (6) PTO pulse/direction outputs |
| Axis Profile(s) | relative/absolute positioning + velocity mode + trapezoid + S-curve + electronic gearing + camming + following + homing + jogging + inching + teach functions + linear interpolation + ellipse interpolation + helical interpolation + software limit switches + online edit + x-y trend view |
| Program Memory | 384 KB |
Example Applications Directory
Download
Interactive Guide
Download
LS Electric EtherCAT Tutorial
Download
LS PLC User Manual
Download
PLC Installation Guide
Download
PLC Statement of Direction
Download
Product Cut Sheet
Download
Product Line Brochure
Download
Technical Specifications
Download
XEM PLC Firmware
Download
XEM-DN32HP 2D Drawing
Download
XEM-DN32HP STP 3D Model
Download
XG5000/XG-PM PLC Programming Software
Download